Technical data

Max. Airflow 700 m³ / h / 412 cfm
Max. Static Pressure 4000 Pa
Power 600 W
Filtration System 5-Stage Filtration
Noise Level ≤ 65 dB

5-Stage Filtration Layer-by-Layer Protection

Delivers 99.99% filtration efficiency at 0.3 μm, capturing ultra-fine dust, smoke, and aerosols. Final-stage filtration for fine and ultrafine particles before clean air is discharged.

Adsorbs VOCs, odors, and gas-phase molecules. With H11 HEPA, no particles or odors escape.

Targets 1–5 μm fine particles and removes 85% of 0.3 μm dust, which reduces the load on the carbon and HEPA layers.

Captures coarse dust particles ≥ 5 μm with over 85% filtration efficiency and helps protect downstream filters.

Captures up to 99.9% of sparks, high-temperature particles, oil mist, and large debris before they reach the filter stack.

Deep Odor & VOC Removal Protecting Your Breathe

Standard Honeycomb Structure

Traditional honeycomb carbon relies on porous adsorption to reduce common odors and airborne contaminants.

Thunder Air MOF Structure

Thunder Air’s MOF carbon structure is designed for higher VOC adsorption efficiency, helping capture odors and gas-phase pollutants generated during laser cutting and engraving.

Built for Continuous Production

Handles continuous use with longer filter service life, helping reduce frequent replacement and keep daily production running smoothly.

Thunder Air

Up to 3× Longer Service Life

Protected by SS, G4 & F8 filters

Hobby Standard System

Need Frequent Replacement

Insufficient Pre-filtration Protection

Top-Mounted Fan
for Stronger Performance

  • 0.28㎡ Dimension & Movable
  • Reduces Noise by >5 dB
  • <10% Vibration Amplitude
  • Zero Reverse Resistance

Faster Smoke Removal

Powered by up to 700 m³/h airflow and 4000 Pa static pressure, Thunder Air removes smoke faster to keep production moving with less waiting.

Filter Maintenance,
Made Easier

No more guesswork. Thunder Air tracks filter status in real time, helping you plan maintenance before performance drops.

  • Green Status
    0-70% filter usage. System operating normally.
  • Yellow Status
    70-90% filter usage. Maintenance recommended soon.
  • Red Status
    90-100% filter usage. Filter replacement required.

Industrial Safety Built into the Air Path

SealGuard Containment Design

A fully sealed metal enclosure helps reduce leakage around key connection points and keeps contaminated air inside the filtration path. This ensures exhaust escape is reduced to below 0.01%, keeping the workspace safe and clean.

SparkShield 40-Layer Maze Protection

The 40-layer wave-shaped structure delivers 99.99% fire protection and 200% coverage area, while reducing airflow resistance by 12%. It prevents sparks and high-temperature particles from igniting the filtration system.

Clean Exhaust Path

With H13 HEPA and MOF carbon, the exhaust is free of fine particles and VOC odors. Even the toughest pollutants are captured before they can escape.

Easy to Use, Built for Convenience

Low Noise, High Comfort

Low Noise, High Comfort

Low Noise, High Comfort

TECHNICAL SPECIFICATIONS

Take a closer look at what Thunder Air has to offer

Specification

Thunder Air 700

Dimensions

475x605x972 mm / 18.70″ x 23.82″ x 38.27″

Airflow

MAX. 700 m³/h / 412 cfm

Air Pressure

MAX. 4000 Pa

Compatible Voltage

100-240 V

Noise Level

≤65 dB

Weight

95 kg / 209.44 lb

Power

600 W

Airflow Adjustment

5 Levels

Touch Screen

7″ Touchscreen

Air Duct

Ø150 mm

Control Mode

PLC-controlled speed regulation and differential pressure signal alarm

5-stage Filter System

SS Protection — 99.99% fire protection

G4 Pre-Filter — ≥85% efficiency (≥5 μm)

F8 Medium Filter — ≥85% efficiency (0.3 μm)

MOF Carbon + H11 — Gas-phase molecules & VOC adsorption

H13 HEPA — 99.99% efficiency (0.3 μm)

Frequently Asked Questions

Q1: Do I need a Thunder Air fume extractor for my CO2 laser machine?

Yes, if your laser cutting or engraving process produces smoke, odors, fumes, or visible residue. A dedicated fume extraction system like Thunder Air fume extractor helps capture contaminants at the source and keeps your workspace cleaner and more comfortable.

Q2: Is Thunder Air suitable for schools and makerspaces?

Yes. Thunder Air-700 is suitable for professional workshops, studios, schools, makerspaces, labs, and educational environments where cleaner air, lower odor, and safer laser operation are important.

Q3: Can Thunder Air handle acrylic laser cutting fumes?

Yes. Thunder Air-700 is designed to adsorb VOCs and odors through its MOF carbon layer and capture fine particles through multi-stage filtration. Acrylic cutting can generate strong odors and fumes, so filter life and odor control performance will depend on cutting volume and operating conditions.

Q4: Which Thunder Laser machines are compatible with Thunder Air?

Thunder Air-700 is compatible with major Thunder Laser machines, including Bolt, Nova, Nova Plus, Titan, Titan Pro, and Aurora series.

(1)Bolt Series, including Thunder Bolt, Thunder Bolt Plus, Thunder Bolt Plus 24, Thunder Bolt Pro 22, Thunder Bolt Pro 32 and Thunder Bolt Pro 36;

(2)Nova Series, including Nova 24 and Nova 35;

(3)Nova Plus Series, including Nova Plus 24 and Nova Plus 35;

(4)Titan Series, including Titan 27, Titan 35, Titan Pro 27 and Titan Pro 35

(5)Aurora Series, including Aurora Lite / Aurora UV / Aurora MOPA / Aurora Fiber

Q5: How often do I need to clean or replace the filters?

The maintenance schedule varies for each filtration layer:

The pre-protection unit, which blocks large particles, oil, and sparks, should be cleaned roughly every 30 days to maintain peak performance.

The pre-filter typically requires replacement every 3 to 6 months, while the medium filter can last 6 to 12 months depending on usage.

The activated carbon layer, responsible for adsorbing fumes and odors, generally needs replacing every 3 to 6 months, although it may appear saturated sooner in heavy-use environments.

The high-efficiency HEPA filter provides long-term protection and usually lasts between 12 and 18 months.

Thunder Air’s intelligent monitoring system will notify you when any layer requires attention, ensuring consistent air quality and reliable operation.

Q6: How loud is Thunder Air during operation?

Thunder Air is designed for quiet operation, with a maximum noise level of just 65 dB. This allows it to deliver powerful air extraction while maintaining a comfortable working environment for workshops, studios, and professional facilities.

Q7: How do I know when maintenance or filter replacement is needed?

Thunder Air features an intelligent filter monitoring system that tracks filter status in real time. The control panel provides clear visual indicators to notify users when maintenance or replacement is required, ensuring consistent performance and hassle-free operation.

Q8: Is Thunder Air easy to install and use?

Yes. Thunder Air is designed for plug-and-play installation and simple operation. No complex setup is required—just power on and start using the system immediately.

Q9: Is Thunder Air fume extractor only for laser processing?

No. Thunder Air-700 is also suitable for applications such as electronics assembly, additive manufacturing, welding-related fume control, labs, and other professional environments where dust, fumes, and odors need to be managed.

Get a Quote